General Features
- Size: 200x160x54mm
- Weight: 660g
- Operating Temperature: -55°C to 90°C (-67°F to 194°F)
- Construction: Glass Fibre Reinforced Plastic
- IP Rating: IP67
- Connectors: Deutsch DT 12-Pin
- Update Rate: Up to 1000Hz Input and Output
Inputs
- Type: 16 Analogue inputs, which can also serve as digital inputs
- Each input can measure voltages between 0-28V, independent of the battery voltage.
- Measurement Resolution: 10-Bit, or 0.01V
- Protection: Fully protected for input voltages from -24V to 40V
- Each input has a software selectable 10K Pull-up or Pull-down resistor
- Added Features: Current sourcing for ground switch detection. Configure as active high or low. Configurable Hysteresis voltage. Latching or momentary operation.
Outputs
- Type:
- 19 high side outputs 80A peak, 20A continuous.
- 4 hybrid high/low side outputs 80A peak, 20A continuous.
- 2 reverse current protected outputs, for use with wiper motors. 80A peak, 20A continuous
- Combined: 180A combined output maximum current
- Output Current Control Steps: 100mA (0.1A)
- Protection: Each output is overcurrent, overtemperature, load dump and reverse polarity protected.
- PWM: Each output can be Pulse Width Modulated based on a user defined variable. This can limit the speed of radiator fans, fuel pumps, and dim lights.
- Soft Start: PWM soft start can be enabled on outputs to limit inrush current.
- Added Features: Outputs can be configured to stay on for a specified time after the input is removed, useful for thermo-fans. Outputs can be retried multiple times after an over-current event is detected.
CAN Keypads:
- Support for Blink Marine, Grayhill, and Marlin CAN keypads.
- Up to four keypads can be used at once.
CAN Bus
- Interface: 2x CAN2.0A/B
- Bus Speed: 50kbps, 100kbps, 125kbps, 250kbps, 500kbps, 1000kbps
- Termination Resistor: Both CAN bus ports have software selectable CAN termination resistors.
- Input Stream: 40 Inputs, fully customisable variable parsing with bit masking and math functions. A range of CAN config files are available to comunicate with common ECUs.
- Output Stream: 40 Outputs, fully customisable CAN frame construction with math functions
Data Logging
- Storage: 128Mb of onboard flash storage for logging PDM data
- Speed: 0.1Hz to 50Hz
- Viewing: Data can be downloaded and graphed via the Hardwire Electronics PDM configurator software
Functions
- Output Functions: Each Output can be switched with a user defined function
- Logical Operators: AND, OR, NOR, XOR, NAND, NOR, >, >=, <, <=, Equal, Not Equal
Maths Channels
- Fully customisable Maths Functions
- Mathematical Operators: Mathematical Operators – Addition, Subtraction, Multiplication, Division, Modulus, Choose, Min, Max
- Binary Operators: AND, OR, XOR, Left Shift, Right Shift
Counters
- Configurable counters which increment, decrement, and reset based on user defined conditions
Wi-Fi
- Internal Wi-Fi module allows the user to configure the PDM wirelessly
- The PDM Wi-Fi module can create its own Wi-Fi hotspot to connect to or alternatively the PDM Wi-Fi module can connect to an existing network.
USB
- Type: USB 2.0 Compliant Mini-B
- Driver: Integrated driver for Windows 10
Other
- Rotation: 3-axis rotational position measurement 0.1° resolution
- Gyroscope: 2000°/s 3-axis measurement
- Accelerometer: -8g to 8g 3-axis measurement
PC App
- Name: Hardwire Electronics PDM configurator software.
- Compatibility: Windows 10 machines
- Connectivity: Easy connection to the PDM with USB and windows integrated drivers. No unreliable USB-serial converted needed.
Dimensions

System Diagram