General Features
- Size: 318x124x58mm.
- Weight: 1640g.
- Operating Voltage: 12/24V.
- Operating Temperature: -55°C to 90°C (-67°F to 194°F).
- Construction: Machined Aluminium, Media Blasted and Anodised Black.
- IP Rating: IP67 water and dust resistant.
- Connectors: 2x DTM 12-Pin, 2x DT 12-Pin, 1x DTP 4 Pin.
- Quick Release Radlok Connectors.
- Update Rate: Up to 2000Hz.
- USB connection to a Windows PC. No external programmer is required.
- 50x RGB LED Indicators.
- Free and easy to use configuration software.
- 9-Axis IMU
Inputs
- 16 x 0-27V analogue/digital. inputs w/ frequency measurement.
- Analogue inputs, which can also serve as digital inputs.
- Measurement Range: Each input can measure between 0V-25V
- Measurement Resolution: 16-Bit, or 0.001V
- Fully protected for input voltages from -24V to 40V.
- Integrated Software Selectable 10K Pull up/down resistors allow for positive and ground switching.
- Inputs can be configured as Momentary or Latched, allowing for different types of switches to be used.
- Hysteresis voltage can be added for extra resilience to voltage noise.
- Frequency Measurement up to 300Hz with automatic triggering.
- Software defined filters.
Outputs
- 4x High/Low side, reverse current blocking outputs capable of supplying 30A continuous and 100A Peak
- 6x High/Low side, reverse current blocking outputs capable of supplying 20A continuous and 80A Peak
- 18x High/Low side outputs capable of supplying 20A continuous and 80A Peak.
- 200A combined output maximum current
- Protection: Each output is overcurrent, overtemperature, load dump and reverse polarity protected.
- Output Current Control Steps: 100mA (0.1A).
- Output Current Measurement resolution: 3mA
- Peak fuse and High fuse thresholds can be set to allow for inrush current.
- Trip Mode can be set to Instant (output trips immediately if the current exceeds the threshold) or Normal (acts like a normal physical fuse and allows short current spikes).
- Outputs can be configured to stay on for a specified time after the input is removed, useful for radiator fans or water pumps.
- Outputs can be retried multiple times after an over-current event is detected.
- 1000Hz PWM on each output, with variable duty cycle mapping.
- Soft start on each output for smoother turn on of devices.
- Advanced logic functions can be made to control the output as desired.
Live Data Analysis
- View all PDM data in real-time.
- Data can be viewed in numerical form, or in a graphical format.
- Detect errors and anomalies quickly and efficiently.
- Ensure that the system is working as intended before deploying the PDM in the vehicle.
Functions
- Each Output can be switched with a user defined logic. function, allowing for incredibly flexibility with control.
- Logical Operators: AND, OR, NOR, XOR, NAND, NOR, >, >=, <, <=, Equal, Not Equal.
- Global Cut Off Function can be set to turn off every output at once in an emergency.
- Global Reset Function can be set to re-enable any tripped outputs in real-time.
- Generic Functions can be set to allow for more complicated nesting of functions.
Data Logging
- 128Mb of onboard flash storage for logging PDM data
- 0.1Hz to 50Hz data logging rate.
- Data can be downloaded and graphed via the Hardwire Electronics PDM configuration software.
- Data can be exported as a .csv file for use in external data analysis software.
- Log data based on a logical condition to capture specific events.
Maths Channels
- Real Time Maths Channels can be used to convert data on-the-fly.
- Basic Operations: Addition, Subtraction, Division, Modulus.
- Bit-wise Operations: AND, OR, XOR, Left Shift, Right Shift.
- Advanced Operations: Choose, Min, Max.
CAN Keypads
- The PDM can be controlled via a range of CAN Bus keypads.
- Rotary dials, momentary, latching and multi state buttons are supported.
- Different colour LED button states can be configured.
- Integrated keypad back-lighting with adjustable brightness for day/night driving.
Supported keypads:
Blink Marine CAN Open - 4 to 15 Button.
Blink Marine Race Pad.
Grayhill/Motec/Haltech CAN Open 4-20 Button.
Marlin J1939 8 Button.
CAN Bus
- Interface: 3x CAN2.0A/B.
- Bus Speed: 50kbps, 100kbps, 125kbps, 250kbps, 500kbps, 1000kbps.
- Input Stream: 100 Inputs, fully customisable variable parsing with bit masking and scaling/offsetting. A range of CAN config files are available to communicate with common ECUs.
- DBC File importing.
- Output Stream: 100 Outputs, fully customisable CAN. frame construction with scaling/offsetting.
- Generic Output Stream with DBC file available.
- NIO Expansion for more system IO.
- Software selectable CAN termination resistors.
CAN Bus Analyser
- Fully integrated CAN bus analyser.
- Monitor all CAN bus traffic in real-time.
- Log CAN bus data to a .csv file and export it for external analysis.
- Send arbitrary CAN Bus messages onto the bus - useful for configuring CAN bus devices in your system.
LIN Bus
- 1x LIN Bus interface
- Import and export LDF Files
- Control and communicate with OEM sensors and actuators.
PC App
- Name: Hardwire Electronics PDM configurator software.
Compatibility: Windows 10 machines
Connectivity: Easy connection to the PDM with USB and windows integrated drivers. No unreliable USB-serial converted needed